The first commercial measurement system that captures directly the cavitation load acting on flow
guiding surfaces.
Output: Mechanical Power - a measure for the local damage energy
- Simple and direct measurement of local cavitation aggressivity
- Logarithmic output signal allows a power measurement range over 5 orders
- Integrated transformation of high bandwidth cavitation signal to low bandwidth output signal reduces
processing and memory requirements without loss of information
- Higher accuracy through integrated temperature compensation
- USB 2.0 data transfer and power supply
Artikelnummer: CAPWR0X
Channels: 1
Resolution of A/D-converter: 16 bit
Bandwidth: 3 kHz ... 30 MHz
Max. Static Pressure on sensor: 10 MPa
Output sample rate: 50 kHz
Operating temperature: -20 ... 60 °C