RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

Über dieses Produkt

WebsiteBesuchen Sie die Produktseite
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
Ähnliche Produkte
1/15
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATH...
DE-72175 Dornhan
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
RE-2Y(St)H-TIMF & RE-2X(St)H-TIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-T...
DE-72175 Dornhan
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H
RE-2Y(St)H & RE-2X(St)H
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & M...
DE-72175 Dornhan
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF
INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-TIMF,MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-TIMF,MULT...
DE-72175 Dornhan
RE-2Y(St)2YSWAY-fl-TIMF
RE-2Y(St)2YSWAY-fl-TIMF
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cable...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H MP
RE-2Y(St)H & RE-2X(St)H MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2Y(St)Y-fl
RE-2Y(St)Y-fl
INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for...
DE-72175 Dornhan
RE-2Y(St)H & RE-2X(St)H-MP
RE-2Y(St)H & RE-2X(St)H-MP
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H,SINGLE & MUL...
DE-72175 Dornhan
RE-2G(St)HSWAH-CI-TIMF  FE180
RE-2G(St)HSWAH-CI-TIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR ...
DE-72175 Dornhan
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl
INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of a...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZ...
DE-72175 Dornhan
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
RE-2Y(St)HSWAH&RE-2X(St)HSWAH
HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATH...
DE-72175 Dornhan
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF
HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED...
DE-72175 Dornhan
RE-2G(St)HSWAH-CI-PIMF  FE180
RE-2G(St)HSWAH-CI-PIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SH...
DE-72175 Dornhan
Trend-Produkte
1/15
Gebrauchte CNC-Fräsmaschinen
Gebrauchte CNC-Fräsmaschinen
SH-Werkzeugmaschinen Sascha Hof jun.
DE-86720 Nördlingen
AdBlue 1000 Liter IBC Container
AdBlue 1000 Liter IBC Container
Moser Handels GmbH
DE-86447 Todtenweis
yun express
yun express
Meine Sendungsverfolgung
DE-18439 Stralsund
Sanitärcontainer
Sanitärcontainer
MR Service GmbH & CO. KG
DE-46147 Oberhausen
Ankauf KFZ Kompletträder Reifen Räder Felgen
Ankauf KFZ Kompletträder Reifen Räder Felgen
Lagerclean GmbH
DE-33129 Delbrück
SOLID
SOLID
HBU GmbH
DE-19230 Bobzin
Hartfaserplatten
Hartfaserplatten
Wemaflex GmbH Holzwerkstoffe
DE-33034 Brakel
FTW Scharnierbandförderer
FTW Scharnierbandförderer
FTW Werner Würth GmbH
DE-58540 Meinerzhagen
STAHLWERK Druckluft Kompressor ST 510 pro – 10 Bar
STAHLWERK Druckluft Kompressor ST 510 pro – 10 Bar
STAHLWERK Schweissgeräte GmbH
DE-53332 Bornheim
Schiffsbau
Schiffsbau
Lakowa Gesellschaft für Kunststoffbe- und -verarbeitung mbH
DE-02681 Wilthen
JOTUN Demidekk Täckfärg - deckender Holzschutz
JOTUN Demidekk Täckfärg - deckender Holzschutz
Skohautil GmbH
AT-4303 St. Pantaleon / Erla
Scherenhebebühne 3000kg 230V/400V
Scherenhebebühne 3000kg 230V/400V
fradashop GmbH
DE-49716 Meppen
SOLARWATT Glas-Glas-Solarmodule
SOLARWATT Glas-Glas-Solarmodule
activ solar Schweiz GmbH
CH-8617 Mönchaltorf