Über dieses Produkt
zum Testen und Herstellung von verschiedenen elektronischen Vorrichtungen in der Telekommunikation, Medizin, Auto- und HF-Komponenten benutzerfreundliche Fernsteuerschnittstelle
PROTEC A333 Network Analyzer 300 kHz to 3,2 GHz
Display 10,4 Inch Color LCD ( 800x600) Touch Screen
User Interface USB2.0, Ethernet, Keyboard, Printer, Video
Measurement Range
Frequency Range 300 kHz to 3,2 GHz
Impedance 50 Ohm ( 75 Ohm )
Test Port Connectors N-type, Female
Number of Test Ports 2
Frequency Accuracy +/- 5 ppm
Frequency Resolution 1 mHz
Number of Test Points, User selectable 2 to 10001
IF Bandwidth settings: 1 / 1,5 / 2 / 3 / 5 / 7 / 10 steps 10 Hz to 30 kHz
Dynamic Range at 2 to 3.200 MHz / at IF BW 10Hz >125 dB / typical 130 dB
Measurement Time per Point at 30 kHz IF BW 125 µs
Measurement Range
Test Port Output
Power Range -45 to +10 dBm
Power Accuracy < 1 dB
Power Resolution 0,05 dB
Harmonic Distortion -3 dBc
Test Port Input
Match without System Error Correction > 25 dB
Damage Level + 26 dBm
Damage DC Voltage 35V
Measurement Capabilities
Number of measurement channels Up to 16 independent measurement channels. Each channel is couplet to stimulus response settings incl. frequency range and number of points
Number of Windows Each measurement channel has a display Window
Measurement parameters S11, S12,S21, S22
Measurement parameters conversion To convert S-Parameters into reflection impedance, transmission
Data formats Impedances, refection admittance, and 1/S
Log magnitude, linear amplitude, phase, expanded phase, group delay
SWR, real, imaginary, Smith chart, polar.
Data markers 10 independent marker per trace. Reference markers available for delta
markers operation, Smith chart format includes 5 marker formats:
Linear amplitude / phase, log magnitude / phase, real/ imaginary, R+jX
and G+jB. Polar chart format includes 3 marker formats:
linear magnitude / phase, log magnitude / phase, real/ imaginary.
Markers function
Marker search Max value, Min value, peak, peak left, peak right, target, target left,
target right, multi-target, bandwidth parameter with user defined bandwidth
Marker to function Set start, stop, center to active marker stimulus , set reference to active
Marker response value, set electrical to group delay at active marker
Search range user definable
Tracking Performs marker search continuously or on demand.
Time domain functions
Transformation Selectable transformation type from bandpass, lowpass impulse,
lowpass step. Selectable window from maximum, normal an minimum.
Gated function Selectable gated filter type from bandpass, notch.
Selectable gate shape from maximum, normal and wide.
Source control
Sweep type Linear sweep, segment sweep, log sweep and power sweep.
Segment sweep Define independent sweep segments. Set number of points, test port,
power levels, IF bandwidth, delay time independently for each segment.
Sweep trigger Set to continuous, hold or single sweep
Power Set source power from -45 dBm to 10dBm. The power slope function
compensates source power level error with internal , external or manual trigger.
Trace functions
Display data Current measurement data, memory data or both simultaneously
Trace math Vector addition, subtraction, multiplication or division of measured
complex values and memory data
Title Add custom title to each channel window.
Titles are printed on hardcopies of displayed measurements.
Auto scale Automatically selects scale resolution and reference value to vertical
center the trace.
Electrical delay Offset measured phase or group delay by a defined
amount of
electrical delay in seconds.
Phase Offset measured phase or group delay by a defined amount in degrees.
Statistics Calculates and displays mean, standard deviation and peak
to peak deviation amount in degrees.
Programming function
COM / DCOM Automation LAN, GPIB ( optional )